Intech Micro I/O Remote Stations:

Please select a product below:

2300-RTD62300-NET

2300 Series - Input/Output Remote Stations

The Intech Micro 2300 series is a system of modular I/O Remote Stations, which add an even lower cost option to Intech’s already extensive intelligent I/O Remote Station family, which connect automatically to the Intech MicroScan V5 logging plus SCADA software package.

The 2300 series I/O stations are made up of stand-alone Digital and Analogue—Input/Output stations.



Download 2100 Series Sales Brochure

2100-A16

2100-A16 - Analogue Input Remote Station; and Intelligent Multiplexer

16 Universal Analogue Inputs that are software programmable using the user friendly MicroScan software.

Each input can be configured for any of the following inputs: Thermocouple, RTD Pt100, Pt1000, mA, mV & V.

2100-A16-NET - Ethernet Adapter



2400-A16

2400-A16 - Remote Station / Intelligent Multiplexer / Remote I/O

This station has all the friendly features of a monitoring station. The Isolated Universal Analogue Inputs are software programmable using the user friendly MicroScan v5.1 or Station Programmer software. Each input can be configured for any of the following inputs: RTD Pt100/Pt1000, Thermocouple, mA, mV, V & Pulse/Digital.




2100-R2

2100-R2 - Relay Output Expansion

The 2100-R2 is used in conjunction with the 2100-A16 or 2100-A4 to expand the outputs using individual and isolated change over contacts.
Cascade option for a second 2100-R2 (with 2100-A16) enables 32 Digital, Isolated, Relay Outputs!

Note: The 2100-R2 replaces the 2100-R.




2400-R2

2400-R2 - Relay Output Expansion

The 2400-R2 16 Channel Relay Output Expansion Module is used in conjunction with the 2400-A16 / 2400-M-R. This allows the 2400-A16 / 2400-M-R to stand alone as a 16 channel controller/alarm unit.
A second 2400-R2 can then be connected to the first 2400-R2, creating a 32 channel controller/alarm unit. The 2400-R2 relay outputs can be used for any combination of control and alarm functions.




2100-A4

2100-A4 - Analogue Input Remote Station

The universal inputs plus outputs gives this station a lot of flexibility. I/O include 4 analogue inputs, 4 digital inputs, 4 relay outputs plus optional 2 analogue outputs.
Field programmable inputs include thermocouples, RTD, Pt100, mA, mV & V, thermister.




2100-AO

2100-AO - Analogue Output Multiplexer for PLC; and Remote Station

This station provides economical analogue output expansion for PLC's plus is also designed for use as a Remote Station.



2100-D

2100-D - Digital Input/Output Remote Station

The 2100-D offers a high degree of flexibility for both the fully isolated Digital Inputs and Relay Outputs, which are configurable by the user friendly MicroScan Software.


Comms Converters:

2400-IS

2400-IS - Isolating USB/RS232 to RS485/422/232 Converter

The 2400-IS is a compact desktop module that isolates and converts USB or RS232 from a computer to RS485, RS422 or RS232 for communication to a field data logging system.

It’s driver and receiver meet EIA standards RS-422-A and CCITT recommendations V.11 and X.27; and is designed for multipoint transmission on long bus lines in noisy environments. The module can be powered from the computers USB port, or from an external 5Vdc power adapter (not supplied).




2100-IS

2100-IS - Isolating RS232 to RS485/422 Converter

The 2100-IS is a compact, desktop module that isolates and converts RS232 from a computer to RS422 or RS485 for communication to a field data logging system.

The 2100-IS includes thermal shutdown and over current limiting. It also includes audible and fail safe alarms for communications failure, with selectable time delays.




2100-NS

2100-NS - RS232 to RS485/422 Converter, Non-Isolated

The 2100-NS is a compact interface Module that converts RS232 from a computer to RS485 or RS422, for communication to a field data logging system.



USB485

USB485 - USB to RS485 Converter, Non-Isolated

The Intech Micro USB485 is a compact interface module that converts USB to RS485, for communication to a field data logging system. The USB485 is ideal for use with a computer that does not have an RS232 serial port as it eliminates the need for a seperate USB to serial adaptor.

Only use the USB485 for temporary monitoring situations; for industrial environments we recommend using a physical RS232 connection.




2100-NET

2100-NET - Ethernet TCP/IP to Serial Converter

The 2100-NET brings the convenience of the Ethernet to the MicroScan system, allowing single or groups of remote stations to connect to the plants common Ethernet network. Multi MicroScan PC’s can request data directly from the same stations.


2100-M

2100-M - Analogue Input Multiplexer

The 2100-M is used extensively in industrial plants, with proven reliability and accuracy. It comes complete and ready to operate in a compact DIN rail mount enclosure.


2400-M-R

2400-M-R - Analogue Input Multiplexer

The 2400-M-R can multiplex up to 16 Non-Isolated RTD Pt100/Pt1000 inputs, into one output, selectable by a PLC or a Data Logging System.
It uses solid state switches, making it extremely reliable and durable. The PLC only requires two digital outputs and one analogue input to select and receive data from the 2400-M-R.


Protocol Support

2100-XX Protocol Support

2100-XX Protocol Information.

This information details the protocol to access information out of the 2100-XX stations, with a PLC or software written on a computer.



2000-AI

OLD Remote Stations - Discontinued

Information on older discontinued 2000 series as well as other older remote stations and related modules that are no longer in production.